en-Gauge Fire and Life Safety Blog

Fire Extinguishers Extinguish an Estimated 5.32 Million Fires in US in 2010

Posted by Brendan McSheffrey on 10/17/11 11:52 AM

According to the most recent NFPA (National Fire Protection Association) data, in 2010 U.S. fire departments responded to an estimated 1,331,500 fires. These fires resulted in 3,120 civilian fire fatalities, 17,720 civilian fire injuries and an estimated $15,478,000,000 in direct property loss.
fire-extinguisher-in-use

Of these fires 98,000 were responded to in commercial or municipal buildings. Of the over $11.6 billion in property damage, more than $2.6 billion took place in these non-residential structures. This represents an average loss per reported incident in non-residential / commercial structures of over $34,000.

Read More

Topics: Fire Suppression, Home Fire, A Fire Extinguisher, Greenhouse Gas Reduction, Fire Extinguisher Success Stories, Type D Fire Extinguisher, D Fire Extinguisher, B Fire Extinguisher, C Fire Extinguisher, Type A Fire Extinguisher, Type B Fire Extinguisher, Type C Fire Extinguisher, Type ABC Fire Extinguisher, ABC Fire Extinguisher, Success Stories

Electronic Monitoring Works With All Types of Fire Extinguishers

Posted by Brendan McSheffrey on 12/15/10 8:57 AM

All too often we are asked if the en-Gauge technology will work with “X” brand of fire extinguisher 
Amerex-fire-extinguisher-logoand over and over we give the same reply, yes.


medium_buckeye-fire-extinguisher-logoYes to Amerex. Yes to Ansul. Yes to Badger. Yes to Buckeye. Yes to Kidde. Yes, Yes Yes. (Note the alphabetical response).

Any fire extinguisher that requires a pressure gauge can be retrofitted with en-Gauge technology
ansul-fire-extinguisher-logo. A standard pressure gauge has a component UL listing and so does an en-Gauge enabled pressure gauge. So if your building has Buckeye fire extinguishers and you want to retrofit them, you may. Your new project specifies Amerex extinguishers? No problem.

CO2 extinguishers or cartridge operated units, also not a problem. There’s an en-Gauge collar that can be 
badger-fire-extinguisher-logo_(1)utilized with these
kidde-fire-extinguisher-logotypes of units and will monitor for location, position, obstruction and immediate removal.

So as you are looking at the Kidde or Ansul extinguishers in your facility and you want to get them en-Gauge enabled – go right ahead.

 

 

Read More

Topics: Fire Extinguisher, Type D Fire Extinguisher, D Fire Extinguisher, B Fire Extinguisher, C Fire Extinguisher, Type A Fire Extinguisher, Type B Fire Extinguisher, Type C Fire Extinguisher, Type ABC Fire Extinguisher, ABC Fire Extinguisher, Badger Fire Extinguishers, Kidde Fire Extinguishers, Buckeye Fire Extinguishers, Ansul Fire Extinguishers, Amerex Fire Extinguishers

Fire Extinguisher Training - Bullex Digital Solutions for Improved Live Training

Posted by Brendan McSheffrey on 12/7/10 4:58 PM

en-Gauge is great proponent of Fire Extinguisher Training and believes it is a vital aspect of every organization's life safety program.  With that said, we love how Bullex Digital Safety is using innovative technology to improve fire extinguisher training for thousands of people (major bonus, they do so while lowering live training's cost and impact on the environment).


Their Interactive Training System (I.T.S) uses a portable fire system that runs on propane to simulate a fire in its early stages.  The program takes advantage of a Type A water extinguisher for the exercises (cutting down on expense and environmental impact, while allowing for quick and easy refills), even though the fire unit can simulate a class A, B or C fire.  The system reacts to the technique that the student utilizes when trying to put out the fire and ensures that the student fight the fire effectively.  With multiple levels of difficulty, the system can provide a challenge for all students going through fire extinguisher training.


Check out this video for details on how it works:



They also offer a purely digital fire solution (called HotShot) in which students utilize real extinguishers to put out 'digital' fires, while still using real extinguishers.  This provides a great solution for situations in which live fire is not an option.

 



Understanding fire and how to effectively fight it requires fire extinguisher training. With companies like BullEx leading the way, ensuring building occupants are ready in an emergency just got easier.

Read More

Topics: Fire Suppression, A Fire Extinguisher, Fire Extinguisher, Type D Fire Extinguisher, Environmental Protection, D Fire Extinguisher, Fire Extinguisher Training, B Fire Extinguisher, C Fire Extinguisher, Type A Fire Extinguisher, Type B Fire Extinguisher, Type C Fire Extinguisher, Type ABC Fire Extinguisher, Environment, ABC Fire Extinguisher

FIRE EXTINGUISHER TYPES - ABC FIRE EXTINGUISHER DEFINED

Posted by Brendan McSheffrey on 12/2/10 4:39 PM

Type ABC Fire Extinguisher - This is a multipurpose dry chemical extinguisher.


monoammonium-phosphate

The ABC type is filled with monoammonium phosphate, a yellow powder that is effective at extinguishing fires that 1. involveordinary combustibles, such as wood, cloth, and paper (Type A Fire Extinguishers are also designed to fight this type of fire); 2. involve liquids, greases, and gases (Type B fire extinguishers are also designed to fight this type of fire); and 3: fires involving energized electrical equipment (Type C Fire Extinguishers are also designed to fight this type of fire).


Monoammonium phosphate leaves a sticky residue after use that may be damaging to electrical appliances such as a computers.

Read More

Topics: A Fire Extinguisher, B Fire Extinguisher, C Fire Extinguisher, Type A Fire Extinguisher, Type B Fire Extinguisher, Type C Fire Extinguisher, Type ABC Fire Extinguisher, ABC Fire Extinguisher

Fire Extinguisher Types Defined

Posted by Brendan McSheffrey on 12/2/10 4:17 PM

There are many different types of fire extinguishers and fire extinguisher manufactures.  The most important thing to understand about fire extinguisher types is that not all fire extinguishers can fight all types of fires. large_fire-extinguisher-in-use

Read More

Topics: Fire Suppression, A Fire Extinguisher, Fire Extinguisher, Equipment, Type D Fire Extinguisher, D Fire Extinguisher, Fire Extinguisher Training, Electronic Monitoring of Fire Extinguishers, B Fire Extinguisher, C Fire Extinguisher, Type A Fire Extinguisher, Type B Fire Extinguisher, Type C Fire Extinguisher