Fire Extinguisher Types - Halon Fire Extinguishers
Halon Fire Extinguishers
Halon fire extinguisher are a specialty type of fire extinguisher that contain a gas that interrupts the chemical reaction that takes place when fuels burn. This type of fire extinguisher is often used to protect valuable electrical equipment since they leave no residue.
Halons are fire extinguishing agents which are gaseous when discharged and are extremely popular in the aircraft industry, as well as in certain technology marketplaces because Halons are electrically non-conducting. Halons are in almost universal use in aircraft fire extinguishers.. They exist in two forms:
Halon 1211 is used only in portable extinguishers and is a streaming agent. A halon fire extinguisher has a limited range, usually 4 to 6 feet
Halon 1301 is used only in fixed extinguisher installations and is a total flooding agent.This type of extinguisher is commonly found in computer server rooms and clean rooms.
According to SkyBrary, a wiki focused on aviation safety:
Both Halon variants work by a combination of chemical and physical effects. The chemical effects, which are dominant in their overall effect, are achieved by the atoms in the gas directly inhibiting combustion in two different ways:
Bromine, Iodine and Chlorine atoms act catalytically so that each atom participates repeatedly in the scavenging of important free radicals from the combustion gases.
Fluorine atoms react with free radicals and form strong chemical bonds which neutralise combustion but can only do so once and are then “consumed.” The physical effects are both temperature reduction and dilution.
Temperature reduction occurs, whenever a non-reactive gas is added to a flammable gas, because the heat liberated by the reaction of oxygen molecules with a fuel source must be distributed into the overall environment. The rate of the combustive chemical reaction decreases rapidly with reductions in temperature and, if the concentration of added inert gas is high enough, the flame chemistry fails altogether.
Halon gas mixtures are not only inert but of low temperature when released from their pressurised state. Dilution is a simple matter of reducing the collision frequency of the oxygen and fuel source so that there is a reduction in chemical reaction rates. The magnitude of this effect, however, is relatively small compared to chemical inhibition and thermal effects, the former of these being the predominant one.
The chemical consituents in Halon gases, and the products of the reactions they produce when used to fight fires, have been identified as causing damage to the Ozone layer. Halon is still in use today, but is falling out of favor for many uses due to its environmental impact. Europe, and Australia have severely restricted its use, since the Montreal Protocol of 1987. It is however still in use in the United States, the Middle East, and Asia in limited ways. Since the Montreal Protocol Halon is one of the only ozone depleting chemicals with concentrations still rising, due to the release of fire extinguishing equipment already deployed.
A few 'clean agent' alternatives have been appearing on the market as an alternative to Halon extinguishers, including:
Halotron I extinguishers, like carbon dioxide units, are "clean agents" that leave no residue after discharge. Halotron I is less damaging to the Earth's ozone layer than Halon 1211 (which was banned by international agreements starting in 1994). This "clean agent" discharges as a liquid, has high visibility during dischage, does not cause thermal or static shock, leaves no residue and is non-conducting. These properties make it ideal for computer rooms, clean rooms, telecommunications equipment, and electronics. These superior properties of Halotron I come at a higher cost relative to carbon dioxide.
FE-36TM (Hydrofluorocarbon-236fa or HFC-236fa) is another "clean agent" replacement for Halon 1211. This DuPont-manufactured substance is available commercially in Cleanguard® extinguishers. The FE-36 agent is less toxic than both Halon 1211 and Halotron I. In addition, FE-36 has zero ozone-depleting potential; FE-36 is not scheduled for phase-out wheras Halotron I production is slated to cease in 2015. A 100% non-magnetic CleanGuard model is now available.
Reading the American College & University Presidents’ Climate Commitment is a positive experience. As one colleague said to me, “I felt hopeful after reading it that so many smart people are throwing the weight of their institutions behind finding the answers to climate change.” I couldn’t agree more.
In their commitment, they lay out their mission:
We believe colleges and universities must exercise leadership in their communities and throughout society by modeling ways to minimize global warming emissions, and by providing the knowledge and the educated graduates to achieve climate neutrality. Campuses that address the climate challenge by reducing global warming emissions and by integrating sustainability into their curriculum will better serve their students and meet their social mandate to help create a thriving, ethical and civil society. These colleges and universities will be providing students with the knowledge and skills needed to address the critical, systemic challenges faced by the world in this new century and enable them to benefit from the economic opportunities that will arise as a result of solutions they develop.
They also commit their institutions to taking key steps and reaching targeted milestones in pursuit of achieving climate neutrality “as quickly as possible”. One of the most effective ways for the schools to reduce emissions is by committing to ‘green’ building programs, like LEED, for new construction projects and retrofits.
While we vigorously applaud these efforts, the fact is that the carbon emissions generated by just one major fire event can eliminate all of the carbon mitigation benefits accrued via those green building projects. FM Global calculates that fire and risk of fire increases the carbon emissions of buildings by 3% over their lifetime. With this in mind, it is vital to take aggressive steps to minimize fire risk when implementing any carbon reduction plan.
I encourage you to read The Environmental Impact of Electronically Monitored Fire Extinguishers. This White Paper reviews the greenhouse gas impacts of fire as well as the critical carbon mitigating effects of fire extinguishers and in particular electronically monitored extinguishers. Some of the key findings from the report include:
Fast and early fire suppression with fire extinguishers is the most environmentally-friendly way (carbon emitted, water use, water pollution, additional pollution) to extinguish fire
Empty and missing fire extinguishers have been a contributing factor to large conflagrations likely contributing thousands of tons of CO2 to the atmosphere annually
Manual inspections of fire extinguishers are a contributing factor in greenhouse gas emissions
Electronic monitoring of fire extinguishers can be highly beneficial in reducing carbon emissions, lowering water consumption and minimizing toxic material release
Download this free white paper and learn about the most effective way to ensure your Climate Commitement isn’t put at risk by unneccesary fires.
This past week I stayed in Miami in a boutique size, big chain hotel. My stay at the hotel was mostly terrific. Helpful and friendly staff, clean rooms and well kept facilities made my stay very pleasant. Even in this well run hotel, however, the fire extinguisher outside my room was empty.
Walking to my room, I noticed the Class ABC dry chemical fire extinguisher on the 9th floor had lost pressure The pressure gauge read empty. There was no visible means to tell when it was last inspected. The fire extinguisher was in a locked cabinet.
I informed the front desk to the problem on both Saturday the 18th and Sunday the 19th, and yet the inoperable fire extinguisher remained in service through my return to the hotel on the Wednesday the 22nd.
On Wednesday the 22nd, I again informed the front desk and stressed why having no usable fire extinguishers on the 9th floor was such a bad idea. When I checked on the 23rd, nothing had been done although it was assured it would get fixed.
During both my visits to the hotel there was construction being done on the 9th floor, and the only visible fire extinguisher was the empty, inoperative fire extinguisher close by in the hall. This creates a dangerous workplace situation, as well as a situation where hotel guests are at increased, unnecessary risk.
During my second visit I mentioned this issue to a member of the wait staff while asking who to talk to about this. He said that he was not surprised as there has been “an empty one in the kitchen for months”.
I can’t say how long the fire extinguisher was empty. I can say it showed no signs of vandalism and it may have been inspected to code. It likely just leaked.
I do not know if has been fixed.
Yet again, proof of a structure put at risk due to 30 day fire extinguisher inspections being insufficient.
Here is a video of the 9th floor to give you an idea of the actual situation.
Fire extinguisher inspection
There are building owners and managers in all sectors who neglect 30 day fire extinguisher inspections, To those that do, I say, you’re making a mistake. You need to respect the fire codes and get the inspection job done or start monitoring your fire extinguishers.
Fire extinguishers and fire systems as a whole are not infallible, buildings need layers of fire protection, fire extinguishers are layer #1 in stopping a small fire from becoming a blaze. Fire extinguishers in commercial structures in the United States stop more than 500 fires everyday* That includes an estimated 20 times everyday in hotels.
Fire Extinguishers are the first line of defense when a fire incident occurs. For the extinuisher to do its job, it must be available, accessible and function properly - all things the en-Gauge electronic fire extinuisher monitoring solution insures.
With that said, we love to read stories about Fire Exinguishers doing their job and putting out fires or helping people control fires until help arrives or they can evacuate.
Here is a list of Fire Extinguisher Success Stories from the last few days:
In Springfield, MA an employee at Smith and Wesson quickly put out a fire at one of the gun manufacturers buildings. According to the article by Channel 22 News at WWLP.com:
Captain Mike Richard of the Springfield Fire Department told 22News that the employee used a fire extinguisher to put out the fire, which started at Smith & Wesson Building R around 6:00 A.M. ...
Richard says the employee’s action saved the building. He also said that the employee had received training on the use of the extinguisher, which is very important.
Great story, made better by the fact that the employee was part of the S&W emergency response team and had been trained in the proper use of Fire Extinguishers.
On Veteran's Day, an assistant High School Principal - a veteran himself - extinguished a fire with a fire extinguisher at Whitemarsh High School in Pennsylvania. According to The Times Herald:
Assistant Principal Dan Balek, a veteran, was on hand to save the day at Plymouth Whitemarsh High School (PWHS) after part of the east wing faculty kitchen area caught fire Thursday afternoon.
While the cause of the fire remains unclear, school spokesman Dave Sherman said Balek happened to be in the area at the time.
"The school was evacuated briefly and (Balek) used a fire extinguisher to put out the fire before the fire department arrived," said Sherman.
It is common to hear about fires put out prior to the fire department arriving. This emphasizes the importance of consistent monitoring of the fire extinguishers to be confident that they are available and ready to work.
A small fire on the Orange Line in the Downtown Crossing MBTA Station in Boston caused disruption of service and the evacuation of the station, but no injuries were reported. According to Boston.com:
A small fire in the Downtown Crossing MBTA station Saturday night disrupted subway service, but caused no reported injuries, Boston Fire Department spokesman Steve MacDonald said.
Officials evacuated the station as a precaution after the fire, which occurred about 10 p.m., MacDonald said. The flame started around the wheel of a Orange Line train, and firefighters quickly put it out with a fire extinguisher before it could make a lot of smoke, MacDonald said.
Intentionally Set School Fire in Washington State Supressed with Fire Extinguisher
A fire intentionally set in the 3rd floor girls bathroom at Kitsap High School in Kitsap, Washington was identified and extinguished by school officials after smoke was reported. According to the Central Kipsap Reporter:
School officials were alerted to the fire and used a fire extinguisher to snuff out the small blaze, according to a statement from the fire department. No one was injured.
Estimates put the damage at about $2,000.
District spokesman David Beil said about 1,200 students were temporarily evacuated.
According to a student at the school who commented on the article:
omg me and my bros and my friendsgo to this schoolitwas so creepy!! there was smoke everywhere!!
We love this comment and think that the english teachers at the school probably will too.
According to the Kitsap Sun - yup, the same Kitsap - a fire at a manufacturing plant on Bainbridge Island experienced an electric fire:
Employees at the rod-and-reel plant noticed sparks and a flame coming from the wall socket about 8:30 p.m., according to a report from Bainbridge Island Fire Department. An alert employee grabbed a fire extinguisher and put out the blaze.
As a precaution, the building was evacuated.
When firefighters arrived, they checked the outlet and surrounding wall with a thermal imaging camera and found no lingering heat. Employees were allowed to go home, and maintenance staffers took over repairs.
This is a perfect example of why you call the Fire Department, even if you think you have fought the blaze successfully. Fires that may look like they have been extinguished can smolder for hours and come back to life later. The Fire Department knows what to look for and should always be contacted in any fire emergency.
Remember, make sure you perform your yearly fire extinguisher inspections and to ensure that your extinguishers are available, accessable and ready to use 24 X 7, 365, rely upon en-Gauge. The only electronically monitored fire extinguisher solution. Contact Us today to Learn More
Two Texas companies learned the hard way this week that failure to provide a safe workplace - and in particular accessible and functioning fire extinguishers - is very bad for business. OSHA, the US Department of Labor's Occupational Safety and Health Administration, cited the companies on multiple willful and serious violations and levied fines that equal almost $400,000.
The U.S. Department of Labor's Occupational Safety and Health Administration has issued Texas Linen Company Ltd. five serious and 15 repeat citations following a safety and health inspection at the company's facility in Austin, Texas. Proposed penalties total $126,400.
...Repeat citations were issued alleging a failure to keep flooring dry; cover floor holes; provide machine guards for rotating parts, points of operation, and sprockets and chains; provide illuminated exit signs and clear exit access; provide properly identified locks for machine servicing; and provide working and easily accessible portable fire extinguishers.
In a separate incident, OSHA has cited U.S. Minerals Inc. with three alleged willful and 35 alleged serious violations for exposing workers to multiple safety and health hazards at the company's facility in Galveston. Proposed penalties total $273,000.According to the Houston Examiner:
Serious violations include failing to provide covers on chute floors, failing to remove damaged portable metal ladders from service, failing to ensure compressed gas cylinders were properly secured, failing to provide fire extinguishers where combustible and flammable materials were stored and failing to develop and document machine specific lockout/tag out procedures for equipment. A serious violation is one in which there is substantial probability that death or serious physical harm could result from a hazard about which the employer knew or should have known.
...Speaking on this issue, Mark Briggs, OSHA's area director for the Houston South Area Office said, “Employers' disregard for worker safety will not be tolerated. This company jeopardized the safety of its employees
As a company that has a history of over 40 years in fire protection and life safety, we understand how vital the work is that OSHA does in ensuring workplace safety. Unfortunately, there are large spans of time in between inspections. That is why it the en-Gauge fire extinguisher monitoring solution is so important to workplace safety. The en-Gauge system monitors fire extinguishers 24 X 7 X 365 and ensures that these critical life safety devices are available, accessible and ready for use when needed. Protect your company, lower your risk and make sure your employees are safe.
A very sad story. In Albuquerque, NM a 1 year old toddler was killed in a fire that was started when her 4 year old sister was playing with a lighter. Unfortunately, it is possible that this tragedy did not need to happen.
According to KOB.com, the website of Channel 4 news in Albuquerque:
The city found 30 units without working smoke detectors in the complex located near Topke and San Mateo in Northeast Albuquerque.
Officials say that while all units were equipped with a fire extinguisher, every one had expired tags.
The new apartment managers have assured the city that they are working to get all extinguishers checked.
Mitchell’s mother Tataneisha told KOB Eyewitness News 4 that she had tried to put the fire out using the extinguisher but she couldn’t get it to work.
These types of stories are all too common. When a fire is in its early stages, we rely on fire extinguishers to be available and functional. When they don't work, the ability to manage the fire is greatly compromised, sometimes with tragic consequences.
Fire extinguishers must be monitored, maintained and accessible in order to ensure this type of terrible story doesn't keep repeating itself.