Fire Extinguisher Training - Bullex Digital Solutions for Improved Live Training
en-Gauge is great proponent of Fire Extinguisher Training and believes it is a vital aspect of every organization's life safety program. With that said, we love how Bullex Digital Safety is using innovative technology to improve fire extinguisher training for thousands of people (major bonus, they do so while lowering live training's cost and impact on the environment).
Their Interactive Training System (I.T.S) uses a portable fire system that runs on propane to simulate a fire in its early stages. The program takes advantage of a Type A water extinguisher for the exercises (cutting down on expense and environmental impact, while allowing for quick and easy refills), even though the fire unit can simulate a class A, B or C fire. The system reacts to the technique that the student utilizes when trying to put out the fire and ensures that the student fight the fire effectively. With multiple levels of difficulty, the system can provide a challenge for all students going through fire extinguisher training.
Check out this video for details on how it works:
They also offer a purely digital fire solution (called HotShot) in which students utilize real extinguishers to put out 'digital' fires, while still using real extinguishers. This provides a great solution for situations in which live fire is not an option.
Understanding fire and how to effectively fight it requires fire extinguisher training. With companies like BullEx leading the way, ensuring building occupants are ready in an emergency just got easier.
Fire Extinguishers are your organization's first line of defense against fire and a critical part of your life safety plan. They are designed to put out or control small fires, but it is vital that building occupants understand and get trained on the basics of fire safety and fire extinguisher use.
Why is fire extinguisher training important?
According to the University of Norhtern Iowa:
A fire is the most common type of emergency for which all businesses must plan. A critical decision when planning is whether or not employees should fight a small fire with a portable fire extinguisher or simply evacuate. Small fires can often be put out quickly with a portable fire extinguisher. However, to do this safely, the employee must understand the use and limitation of a portable fire extinguisher and the hazards associated with fighting fires.
What does fire extinguisher training consist of?
For an individual to properly assess and react in a fire situation, Fire Extinguisher Training generally consists of several components.
Fire Basics.
The components of fire, how fires start and spread.
Fuel Classifications.
Understanding the four types of fuel sources for fires. A. General Combustibles like wood, cloth, paper, rubber; B. Flamable liquids, gases, greases, Petroleum products; C. Energized electrical equipment, and; D. Combustible metals like sodium, potassium, magnesium
Types of Extinguishers.
What are they types of extinguisher and which types of fires they can be used on.
How Fire Extinguishers Work.
Components of a fire extinguisher, how they suppress various types of fires, pressure systems, etc.
Rules for Fighting a Fire.
What to do before fighting a fire, understanding what is burning, understanding how to approach a fire, identifying your evacuation path, assessing a fire's progress, etc.
How to Use a Fire Extinguisher Properly.
How the P.A.S.S. (Pull, Aim, Squeeze, Sweep) technique works, why it is important and how it is put into practice..
Fire Extinguisher Training is more than just pulling a pin and squeezing. Implementing a fire extinguisher safety program, informing occupants of the specific building's fire safety procedures, understanding the different classes of fires and different types of fire extinguishers, and receiving training on how to fight a fire CAN save lives. There are many professional organizations that can provide detailed fire extinguisher training for your organization. We encourage all businesses to consider this important life safety step.
Type ABC Fire Extinguisher - This is a multipurpose dry chemical extinguisher.
The ABC type is filled with monoammonium phosphate, a yellow powder that is effective at extinguishing fires that 1. involveordinary combustibles, such as wood, cloth, and paper (Type A Fire Extinguishers are also designed to fight this type of fire); 2. involve liquids, greases, and gases (Type B fire extinguishers are also designed to fight this type of fire); and 3: fires involving energized electrical equipment (Type C Fire Extinguishers are also designed to fight this type of fire).
Monoammonium phosphate leaves a sticky residue after use that may be damaging to electrical appliances such as a computers.
Reading the American College & University Presidents’ Climate Commitment is a positive experience. As one colleague said to me, “I felt hopeful after reading it that so many smart people are throwing the weight of their institutions behind finding the answers to climate change.” I couldn’t agree more.
In their commitment, they lay out their mission:
We believe colleges and universities must exercise leadership in their communities and throughout society by modeling ways to minimize global warming emissions, and by providing the knowledge and the educated graduates to achieve climate neutrality. Campuses that address the climate challenge by reducing global warming emissions and by integrating sustainability into their curriculum will better serve their students and meet their social mandate to help create a thriving, ethical and civil society. These colleges and universities will be providing students with the knowledge and skills needed to address the critical, systemic challenges faced by the world in this new century and enable them to benefit from the economic opportunities that will arise as a result of solutions they develop.
They also commit their institutions to taking key steps and reaching targeted milestones in pursuit of achieving climate neutrality “as quickly as possible”. One of the most effective ways for the schools to reduce emissions is by committing to ‘green’ building programs, like LEED, for new construction projects and retrofits.
While we vigorously applaud these efforts, the fact is that the carbon emissions generated by just one major fire event can eliminate all of the carbon mitigation benefits accrued via those green building projects. FM Global calculates that fire and risk of fire increases the carbon emissions of buildings by 3% over their lifetime. With this in mind, it is vital to take aggressive steps to minimize fire risk when implementing any carbon reduction plan.
I encourage you to read The Environmental Impact of Electronically Monitored Fire Extinguishers. This White Paper reviews the greenhouse gas impacts of fire as well as the critical carbon mitigating effects of fire extinguishers and in particular electronically monitored extinguishers. Some of the key findings from the report include:
Fast and early fire suppression with fire extinguishers is the most environmentally-friendly way (carbon emitted, water use, water pollution, additional pollution) to extinguish fire
Empty and missing fire extinguishers have been a contributing factor to large conflagrations likely contributing thousands of tons of CO2 to the atmosphere annually
Manual inspections of fire extinguishers are a contributing factor in greenhouse gas emissions
Electronic monitoring of fire extinguishers can be highly beneficial in reducing carbon emissions, lowering water consumption and minimizing toxic material release
Download this free white paper and learn about the most effective way to ensure your Climate Commitement isn’t put at risk by unneccesary fires.
This past week I stayed in Miami in a boutique size, big chain hotel. My stay at the hotel was mostly terrific. Helpful and friendly staff, clean rooms and well kept facilities made my stay very pleasant. Even in this well run hotel, however, the fire extinguisher outside my room was empty.
Walking to my room, I noticed the Class ABC dry chemical fire extinguisher on the 9th floor had lost pressure The pressure gauge read empty. There was no visible means to tell when it was last inspected. The fire extinguisher was in a locked cabinet.
I informed the front desk to the problem on both Saturday the 18th and Sunday the 19th, and yet the inoperable fire extinguisher remained in service through my return to the hotel on the Wednesday the 22nd.
On Wednesday the 22nd, I again informed the front desk and stressed why having no usable fire extinguishers on the 9th floor was such a bad idea. When I checked on the 23rd, nothing had been done although it was assured it would get fixed.
During both my visits to the hotel there was construction being done on the 9th floor, and the only visible fire extinguisher was the empty, inoperative fire extinguisher close by in the hall. This creates a dangerous workplace situation, as well as a situation where hotel guests are at increased, unnecessary risk.
During my second visit I mentioned this issue to a member of the wait staff while asking who to talk to about this. He said that he was not surprised as there has been “an empty one in the kitchen for months”.
I can’t say how long the fire extinguisher was empty. I can say it showed no signs of vandalism and it may have been inspected to code. It likely just leaked.
I do not know if has been fixed.
Yet again, proof of a structure put at risk due to 30 day fire extinguisher inspections being insufficient.
Here is a video of the 9th floor to give you an idea of the actual situation.
Fire extinguisher inspection
There are building owners and managers in all sectors who neglect 30 day fire extinguisher inspections, To those that do, I say, you’re making a mistake. You need to respect the fire codes and get the inspection job done or start monitoring your fire extinguishers.
Fire extinguishers and fire systems as a whole are not infallible, buildings need layers of fire protection, fire extinguishers are layer #1 in stopping a small fire from becoming a blaze. Fire extinguishers in commercial structures in the United States stop more than 500 fires everyday* That includes an estimated 20 times everyday in hotels.
All too often we are asked if the en-Gauge technology will work with “X” brand of fire extinguisher and over and over we give the same reply, yes.
Yes to Amerex. Yes to Ansul. Yes to Badger. Yes to Buckeye. Yes to Kidde. Yes, Yes Yes. (Note the alphabetical response).
Any fire extinguisher that requires a pressure gauge can be retrofitted with en-Gauge technology. A standard pressure gauge has a component UL listing and so does an en-Gauge enabled pressure gauge. So if your building has Buckeye fire extinguishers and you want to retrofit them, you may. Your new project specifies Amerex extinguishers? No problem.
CO2 extinguishers or cartridge operated units, also not a problem. There’s an en-Gauge collar that can be utilized with these types of units and will monitor for location, position, obstruction and immediate removal.
So as you are looking at the Kidde or Ansul extinguishers in your facility and you want to get them en-Gauge enabled – go right ahead.